Skip to content

BMS_w141 — SW 12 V Pwr Supply Low

Full alert identifier: BMS_w141_SW_12V_Pwr_Supply_Low

Message shown in the car

Power reduced - Unable to charge Service is required

Alert description

The battery management system (BMS) has detected an issue with the low voltage (LV) power supply to the contactors.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

The BMS detects that the input voltage from the LV system is too low.

Clear condition

The BMS detects that the input voltage from the LV system is within nominal range.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ctr Pwr V BMS_a141_ctrPwrV V
Hv Disc V BMS_a141_hvDiscV V
Vehicle 12 V BMS_a141_vehicle12V V
Signal Unit
State BMS_a141_state —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_w141.

Browse all BMS alert codes