BMS_f080 — SW Int HV Disconnect
Full alert identifier: BMS_f080_SW_Int_HV_Disconnect
Message shown in the car
Service is required Schedule service
Alert description
The battery management system (BMS) has detected that the high voltage (HV) battery pack voltage differs from the sum of the brick voltages, making the HV battery unavailable for charging, driving, or supporting the low voltage (LV) battery.
Potential impact
The vehicle is unable to charge or drive. The high voltage (HV) battery cannot support the low voltage (LV) battery.
Set condition
The high voltage (HV) battery pack voltage differs from sum of all the brick voltages.
Clear condition
The high voltage (HV) battery voltage minus the sum of all the brick voltages is within the accepted tolerance for difference.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Pack Current
BMS_
|
A |
Pack Minus
BMS_
|
V |
Pack Plus
BMS_
|
V |
Pack V
BMS_
|
V |
Sum Of Brick V
BMS_
|
V |
| Signal | Unit |
|---|---|
State
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f080.