Skip to content

BMS_f106 — SW All Module Tsense

Full alert identifier: BMS_f106_SW_All_Module_Tsense

Message shown in the car

Service is required Schedule service

Alert description

A battery monitoring board (BMB) detects that both of the thermistors on a module are reporting out-of-bounds temperatures.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

A battery monitoring board (BMB) detects that both of the thermistors on a module are reporting out-of-bounds temperatures.

Clear condition

The BMS detects that the condition clears.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Avg Brick T BMS_a106_avgBrickT
255
SNA
C
Inlet Temp BMS_a106_inletTemp
255
SNA
C
Max Brick T BMS_a106_maxBrickT
255
SNA
C
Min Brick T BMS_a106_minBrickT
255
SNA
C
Signal Unit
T Sensor Err Type BMS_a106_TSensorErrType
0
OUT OF BOUNDS
1
GRADIENT DELTA POS
2
GRADIENT DELTA NEG
—
Module ID BMS_a106_moduleID —
State BMS_a106_state —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f106.

Browse all BMS alert codes