BMS_w106 — SW All Module Tsense
Full alert identifier: BMS_w106_SW_All_Module_Tsense
Message shown in the car
Vehicle may not restart Service is required
Alert description
A battery monitoring board (BMB) detects that both of the thermistors on a module are reporting out-of-bounds temperatures.
Potential impact
Inability to charge, drive, or support the low voltage (LV) system
Set condition
A battery monitoring board (BMB) detects that both of the thermistors on a module are reporting out-of-bounds temperatures.
Clear condition
The BMS detects that the condition clears.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Avg Brick T
BMS_
|
C |
Inlet Temp
BMS_
|
C |
Max Brick T
BMS_
|
C |
Min Brick T
BMS_
|
C |
| Signal | Unit |
|---|---|
T Sensor Err Type
BMS_
|
— |
Module ID
BMS_
|
— |
State
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_w106.