BMS_f117 — SW Delta SOC Weak Short
Full alert identifier: BMS_f117_SW_Delta_SOC_Weak_Short
Alert description
A given brick has an alpha signal below the alert Alpha threshold.
Potential impact
If set and MCU_dSocAlertEnable=1, max charge may be limited; see BMS_u029_dSoc_Limiting.
Set condition
The computed alpha estimate for a brick is repeatedly below the alert Alpha threshold. Note: This Threshold comes via CAN from UI Data Field -> GTW -> BMS via MCU_dSocAlertThreshold.
Clear condition
The CLEAR_SOC1_SNAPSHOT UDS StartRoutine is invoked.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Brick Soc 2
BMS_
|
% |
Delta Soc Alpha
BMS_
|
% |
| Signal | Unit |
|---|---|
Brick ID
BMS_
|
— |
D Soc Alpha Brick Flag
BMS_
|
— |
Dc To Ac Ratio High
BMS_
|
— |
Depth Of Discharge
BMS_
|
— |
Silent Limiting
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f117.