BMS_f164 — SW Brick SOC Imbalance
Full alert identifier: BMS_f164_SW_Brick_SOC_Imbalance
Alert description
The battery management system (BMS) detects a state of charge (SOC) imbalance between bricks associated with the same module.
Potential impact
This alert is primarily informational and is used for logging purposes.
Set condition
The BMS detects that the SOC imbalance between any two bricks associated with a module is above the warning threshold.
Clear condition
All modules report no SOC discrepancies.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Intra Bmb SOC Imbalance
BMS_
|
% |
Max Brick SOC
BMS_
|
% |
Min Brick SOC
BMS_
|
% |
| Signal | Unit |
|---|---|
Bmb ID
BMS_
|
— |
Max Brick SOCID
BMS_
|
— |
Min Brick SOCID
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f164.