Skip to content

BMS_w074 — SW Charging

Full alert identifier: BMS_w074_SW_Charging

Alert description

The battery management system (BMS) has detected an issue with the charger.

Potential impact

Inability to charge.

Set condition

The BMS detects an issue with the charger. Alert log signal data provides information on the specific condition(s) detected.

Clear condition

The BMS detects that the condition clears.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Soc BMS_a074_SOC PCT
Start SOC BMS_a074_startSOC PCT
Timer BMS_a074_timer sec
Signal Unit
OB Cstate BMS_a074_OBCstate
0
UNDEF
1
STANDBY
2
CLEAR FAULT
3
FAULT
4
ENABLE
—
Err Type BMS_a074_errType
0
RSVD0
1
FLT BFORE BMSENBL
2
FLT AFTR CTRSCLSD
3
CRGR NOT ENABLING
4
CRGR FLT AFTER ENBL
5
RSVD5
6
DISCHG WHILE CHG
7
CRGR NOT DISABLING
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_w074.

Browse all BMS alert codes