Skip to content

BMS_w114 — SW FC Contactors

Full alert identifier: BMS_w114_SW_FC_Contactors

Alert description

The Fast Charge (FC) contactors are not ready for precharge.

Potential impact

The vehicle is temporarily unable to charge.

Set condition

The FC contactors are welded or the reported charge port state does not meet the expected state.

Clear condition

The FC contactors are not welded and the charge port state meets the expected states to charge.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Fc Input Voltage BMS_a114_fcInputVoltage V
Line Input Voltage BMS_a114_lineInputVoltage V
Signal Unit
Fc Contactor State BMS_a114_fcContactorState
0
OPEN
1
CLOSED
2
WELDED
3
STATIC TEST PASSED
4
INIT
7
SNA
—
Fc Ctr State Signal Sna BMS_a114_fcCtrStateSignalSna —
Fc Ctr State Signal Timeout BMS_a114_fcCtrStateSignalTimeout —
Fc Ctr State Signal Valid BMS_a114_fcCtrStateSignalValid —
Ok To Precharge BMS_a114_okToPrecharge —
Ready To Close Contactors BMS_a114_readyToCloseContactors —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_w114.

Browse all BMS alert codes