Skip to content

BMS_f023 — SW Contactors Open HWOC

Full alert identifier: BMS_f023_SW_Contactors_Open_HWOC

Message shown in the car

Service is required Schedule service

Alert description

This alert is used as a counter to record the number of hardware overcurrents (HWOC) detected by the battery management system (BMS).

Potential impact

This alert is primarily informational and is used for logging purposes.

Set condition

The BMS detects that the contactors were opened under load because of a HWOC event.

Clear condition

The BMS detects that the condition clears.

Signals to check

These diagnostic fields are associated with BMS_f023. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Hw Oc Count BMS_a023_hwOcCount —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f023.