Skip to content

CC_f003 — CCID Tripped

Full alert identifier: CC_f003_CCIDTripped

Message shown in the car

Unable to charge - Wall Connector GFCI tripped Disconnect and retry or use different equipment

Alert description

Ground fault current exceeded threshold.

Potential impact

Wall connector will not allow charging until ground fault current path is corrected and the test rerun.

Set condition

Ground fault current exceeded threshold.

Clear condition

Ground fault current has been corrected, and the test rerun. Test reruns after 15 minutes (non-EU), cable cycle, or reset button.

Signals to check

These diagnostic fields are associated with CC_f003. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Gfci Rms Current CC_a003_gfciRmsCurrent A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_f003.