CC_f003 — CCID Tripped
Full alert identifier: CC_f003_CCIDTripped
Message shown in the car
Unable to charge - Wall Connector GFCI tripped Disconnect and retry or use different equipment
Alert description
Ground fault current exceeded threshold.
Potential impact
Wall connector will not allow charging until ground fault current path is corrected and the test rerun.
Set condition
Ground fault current exceeded threshold.
Clear condition
Ground fault current has been corrected, and the test rerun. Test reruns after 15 minutes (non-EU), cable cycle, or reset button.
Signals to check
These diagnostic fields are associated with CC_f003. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Gfci Rms Current
CC_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_f003.