CC_f004 — CCID Self Test Fault

Full alert identifier: CC_f004_CCIDSelfTestFault

Message shown in the car

Unable to charge - Wall Connector issue Wall Connector needs service

Alert description

Ground fault detection circuit self-test failed.

Potential impact

Wall connector will not allow charging until the ground fault circuit self-test passes.

Set condition

Ground fault detection circuit self-test failed.

Clear condition

Ground fault detection circuit self-test passed after being rerun. Test reruns after 15 minutes (non-EU), cable cycle, or reset button.

Signals to check

These diagnostic fields are associated with CC_f004. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Gfci Self Test Current CC_a004_gfciSelfTestCurrent A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_f004.