CC_f004 — CCID Self Test Fault
Full alert identifier: CC_f004_CCIDSelfTestFault
Message shown in the car
Unable to charge - Wall Connector issue Wall Connector needs service
Alert description
Ground fault detection circuit self-test failed.
Potential impact
Wall connector will not allow charging until the ground fault circuit self-test passes.
Set condition
Ground fault detection circuit self-test failed.
Clear condition
Ground fault detection circuit self-test passed after being rerun. Test reruns after 15 minutes (non-EU), cable cycle, or reset button.
Signals to check
These diagnostic fields are associated with CC_f004. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Gfci Self Test Current
CC_
|
A |
Check other alerts