Skip to content

CP_w006 — Lost Comms BMS

Full alert identifier: CP_w006_lostCommsBMS

Alert description

Expected Battery Management System (BMS) controller area network (CAN) messages are missing. Charging may not start.

Potential impact

Charging may not start.

Set condition

Charge port (CP) does not receive all expected controller area network (CAN) messages from the Battery Management System (BMS).

Clear condition

Charge port (CP) receives all expected controller area network (CAN) messages from the Battery Management System (BMS).

Signals to check

These diagnostic fields are associated with CP_w006. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
BMS FC Hv Bus Status MIA CP_a006_BMS_FC_hvBusStatus_MIA —
BMS FC Pack Status MIA CP_a006_BMS_FC_packStatus_MIA —
BMS FC Request MIA CP_a006_BMS_FC_request_MIA —
BMS Charge Status MIA CP_a006_BMS_chargeStatus_MIA —
BMS Charger Request MIA CP_a006_BMS_chargerRequest_MIA —
BMS Soc Status MIA CP_a006_BMS_socStatus_MIA —
BMS Status MIA CP_a006_BMS_status_MIA —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_w006.

Browse all CP alert codes