Skip to content

PLCRLY_a090 — Ccs Evse Low Iso

Full alert identifier: PLCRLY_a090_ccsEvseLowIso

Alert description

During a DC fast charging session at a Combined Charging System (CCS) charging station, the Electric Vehicle Supply Equipment (EVSE) detects low isolation resistance.

Potential impact

CCS charging may not start or may be interrupted.

Set condition

The CCS DC EVSE detects low isolation resistance during a charging session.

Clear condition

The CCS DC EVSE reports nominal isolation resistance or the communication channel with the EVSE is no longer established.

Signals to check

These diagnostic fields are associated with PLCRLY_a090. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Evse Iso Status PLCRLY_a090_evseIsoStatus
0
INVALID
1
VALID
2
WARNING
3
FAULT
4
NO IMD
—
Iec Combo State PLCRLY_a090_iecComboState —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PLCRLY_a090.

Browse all PLCRLY alert codes