Skip to content

Compressor RPM Override

Gen3/tasks/PROC_X_COMPRESSOR-RPM-OVERRIDE

What this task does

Set the compressor to a target speed (800-7000 RPM). If sweep is disabled, the compressor will ramp to target RPM and hold that speed for 15 seconds. If sweep is enabled, the compressor will ramp to target RPM in 500 RPM increments and hold at final target RPM for 15 seconds. Note: The routine may skip some RPM values during sweep, or stop short of the target RPM. This is because some vehicles have certain speeds that are avoided.

Vehicle compatibility

Select your vehicle’s hardware to see task details, requirements, and inputs. Availability is confirmed after connection.

Model 3 / Y AMD
Vehicle coverage
2024+ Model 3, 2025+ Model Y, Model Y, Pre-2024 Model 3
Supported connection
Local connection
Vehicle state
Stationary · Parked
Gateway diagnostic level
Factory, DiagLinkActive

Procedure notes

The compressor will operate at high RPMs. To prevent potential damage, ensure the thermal system is fully functional before running this routine. Pumps will run at moderate speed.

Task inputs (2)

Compressor RPM Target

target_rpm · Int

Enter the target compressor speed (800-7000 RPM).

Default: Not specified

Enable Sweep

enable_sweep · Bool

Sweep to RPM target in 500 RPM increments.

Default: false

Model 3 / Y Intel
Vehicle coverage
Model Y, Pre-2024 Model 3
Supported connection
Local connection
Vehicle state
Stationary · Parked
Gateway diagnostic level
Factory, DiagLinkActive

Procedure notes

The compressor will operate at high RPMs. To prevent potential damage, ensure the thermal system is fully functional before running this routine. Pumps will run at moderate speed.

Task inputs (2)

Compressor RPM Target

target_rpm · Int

Enter the target compressor speed (800-7000 RPM).

Default: Not specified

Enable Sweep

enable_sweep · Bool

Sweep to RPM target in 500 RPM increments.

Default: false

Model S / X (2021+) AMD
Vehicle coverage
2021+ Model S, 2021+ Model X
Supported connection
Local connection
Vehicle state
Stationary · Parked
Gateway diagnostic level
Factory, DiagLinkActive

Procedure notes

The compressor will operate at high RPMs. To prevent potential damage, ensure the thermal system is fully functional before running this routine. Pumps will run at moderate speed.

Task inputs (2)

Compressor RPM Target

target_rpm · Int

Enter the target compressor speed (800-7000 RPM).

Default: Not specified

Enable Sweep

enable_sweep · Bool

Sweep to RPM target in 500 RPM increments.

Default: false

Browse all tasks →
Service procedures

Clear DTCs

Clears the diagnostic data on the chosen Electronic Control Unit (ECU). This will clear any active Diagnostic Trouble Codes (DTC). DTC functionality may not exist on all ECUs depending on the platform.

PROC_X_CLEAR-DTCS

Model 3 / Y Model S / X (2021+)
Service procedures

Clear IDB DTCs

Clear the Mando Decoupled Brake (IDB) Diagnostic Trouble Codes (DTC).

PROC-IDB_X_CLEAR_DTCS

Model 3 / Y
Service procedures

Clear RCU DTCs

Clear the Mando Redundant HCU (RCU) Diagnostic Trouble Codes (DTC).

PROC-RCU_X_CLEAR_DTCS

Model 3 / Y
Service procedures

Clear Side View Mirror Fold Type

Executes a routine to clear the side view mirror fold actuator type auto-detected by the Tesla ECU.

PROC_X_CLEAR-MIRROR-FOLD-TYPE

Model 3 / Y