HVP_w012 — Bmb Data Integrity Loss
Full alert identifier: HVP_w012_BmbDataIntegrityLoss
Alert description
The High Voltage Processor (HVP) detects a data integrity loss due to a double break in the Battery Monitoring Board (BMB) chain.
Potential impact
There may be a loss of BMB sensor data.
Set condition
The HVP detects a double break in the BMB daisy chain.
Clear condition
No BMB sensor data loss conditions are detected for a prolonged period of time.
Signals to check
These diagnostic fields are associated with HVP_w012. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bmb Comm Status Type A
HVP_
|
— |
Bmb Comm Status Type B
HVP_
|
— |
Break Location A
HVP_
|
— |
Break Location B
HVP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w012.