Alert description

Secondary Disconnect Controller (SDC) phase voltage sensors are providing irrational values.

Potential impact

Pyro disconnect may not function as expected.

Set condition

Sets when at least one phase voltage measurement remains low while voltage should be constantly switching between low and high.

Clear condition

Clears when all phase voltage measurements are within rational or expected range.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
V Bat SDCR_a015_vBat V
Va SDCR_a015_va V
Vb SDCR_a015_vb V
Vc SDCR_a015_vc V
Signal Unit
Di Switching Pin SDCR_a015_diSwitchingPin —
Reason V Phase Shorted High SDCR_a015_reason_vPhaseShortedHigh —
Reason V Phase Shorted Low SDCR_a015_reason_vPhaseShortedLow —