CC_f011 — Ambient OT
Full alert identifier: CC_f011_ambientOT
Message shown in the car
Unable to charge - Wall Connector too hot Let Wall Connector cool and try again
Alert description
Wall connector printed circuit board assembly (PCBA) temperature is too high.
Potential impact
Wall connector will reduce reported current capability in 25 percent increments until condition clears, or current reaches 0 and charging is stopped.
Set condition
Wall connector PCBA temperature exceeds 100 degC.
Clear condition
Wall connector PCBA temperature falls below 80 degC or user interaction if charging was stopped.
Signals to check
These diagnostic fields are associated with CC_f011. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Pcba Temp
CC_
|
DegC |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_f011.