CC_f013 — Veh Conn OT
Full alert identifier: CC_f013_vehConnOT
Message shown in the car
Unable to charge - Charge handle too hot Check charge handle or charge port for debris
Alert description
Wall connector charge handle temperature too high.
Potential impact
Wall connector will reduce reported current capability in 25 percent increments until condition clears, or current reaches 0 and charging is stopped.
Set condition
Wall connector charge handle temperature exceeds 78 degC.
Clear condition
Wall connector charge handle temperature falls below 58 degC or user interaction if charging was stopped.
Signals to check
These diagnostic fields are associated with CC_f013. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Handle Temp
CC_
|
DegC |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_f013.