CC_f012 — Wall Plug OT

Full alert identifier: CC_f012_wallPlugOT

Message shown in the car

Unable to charge - Wall connection too hot Outlet or Wall Connector wiring must be checked

Alert description

Wall connector input wiring temperature is too high.

Potential impact

Wall connector will reduce reported current capability in 25 percent increments until condition clears, or current reaches 0 and charging is stopped.

Set condition

Wall connector input wiring temperature exceeds 100 degC.

Clear condition

Wall connector input wiring temperature falls below 80 degC or user interaction if charging was stopped.

Signals to check

These diagnostic fields are associated with CC_f012. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Input Wiring Thermopile CC_a012_inputWiringThermopile V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_f012.