CC_f012 — Wall Plug OT
Full alert identifier: CC_f012_wallPlugOT
Message shown in the car
Unable to charge - Wall connection too hot Outlet or Wall Connector wiring must be checked
Alert description
Wall connector input wiring temperature is too high.
Potential impact
Wall connector will reduce reported current capability in 25 percent increments until condition clears, or current reaches 0 and charging is stopped.
Set condition
Wall connector input wiring temperature exceeds 100 degC.
Clear condition
Wall connector input wiring temperature falls below 80 degC or user interaction if charging was stopped.
Signals to check
These diagnostic fields are associated with CC_f012. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Input Wiring Thermopile
CC_
|
V |
Check other alerts