Skip to content

SDCR_a010 — Vref Irrational

Full alert identifier: SDCR_a010_vrefIrrational

Alert description

Secondary Disconnect Controller (SDC) reference voltage (Vref) for current sensor measurement is irrational, making SDC unable to monitor drive unit electrical state.

Potential impact

Pyro disconnect may not function as expected.

Set condition

Sets when SDC reference voltage (Vref) measurement is outside of expected range.

Clear condition

Clears when reference voltage (Vref) is within expected range.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Vref SDCR_a010_Vref V
Boost Rail V SDCR_a010_boostRailV V
Signal Unit
Pgood SDCR_a010_pgood —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a010.