Skip to content

SDCR_a014 — V Bus Irrational

Full alert identifier: SDCR_a014_vBusIrrational

Message shown in the car

Powertrain requires service Vehicle speed and power may be limited

Alert description

Secondary Disconnect Controller (SDC) High Voltage (HV) bus voltage sensor is providing irrational values.

Potential impact

Pyro disconnect may not function as expected.

Set condition

Sets when HV bus voltage measurement is low while HV backup rail is up.

Clear condition

Clears when HV bus voltage measurement is within rational or expected range.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
HV Backup Supply V SDCR_a014_HVBackupSupplyV V
Boost Rail V SDCR_a014_boostRailV V
V Bat SDCR_a014_vBat V
Signal Unit
Reason V Bus Shorted High SDCR_a014_reason_vBusShortedHigh —
Reason V Bus Shorted Low SDCR_a014_reason_vBusShortedLow —
Vbkup Good Fdbk SDCR_a014_vbkupGoodFdbk —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a014.

Browse all SDCR alert codes